Wybierz inny kraj lub region, aby zobaczyć zawartość dla swojej lokalizacji.
Stany Zjednoczone
05:15:01 GMT+0000 (Coordinated Universal Time)



RATR30-XL
Flanged housing unit
Housing units RATR, three-bolt flanged housing units, sheet steel, eccentric locking collar, P seals
Zastępuje
RATR30


Main Dimensions & Performance Data
d | 30 mm | Bore diameter |
H2 | 93 mm | Height flange |
H | 112,7 mm | Height flange |
H | 112,7 mm | Flange width |
U | 29,2 mm | Total height unit |
Cr | 19.500 N | Basic dynamic load rating, radial |
C0r | 11.300 N | Basic static load rating, radial |
Cur | 480 N | Fatigue load limit, radial |
C0r G | 5.000 N | Load carrying capacity (housing) |
Cg | 5.000 N | Load carrying capacity (housing) |
≈m | 0,5 kg | Masa |
Mounting dimensions
J | 90,5 mm | Distance fixing bore |
J | 90,5 mm | Pitch circle diameter (holes) |
N | 10,5 mm | Fixing square |
n | 3 | Number of screwing holes |
Dimensions
A | 8,7 mm | Height housing |
H1 | 38,1 mm | Distance shaft axis |
S | 2,5 mm | Thickness of flange |
V | 71 mm | Shoulder diameter housing |
Additional information
2 | Number of housings | |
FLAN62-MSTR | Housing | |
RAE30-XL-NPP-B | Bearing designation |
Temperature range
Tmin | -20 °C | Operating temperature min. |
Tmax | 120 °C | Operating temperature max. |
Warunki pracy łożyska RATR30-XL
W przygotowaniu dla RATR30-XL
CO₂e spowodowane tarciem podczas pracy
Kompleksowe informacje z natychmiastowymi obliczeniami emisji CO2e naszych produktów rotacyjnych w różnych scenariuszach aplikacyjnych.

Obciążenie
* ObowiązkoweWpływ ruchu
* Obowiązkowe Nastawy parametrów obliczenia
Arcanol MULTI2
Smarnormalna czystość
Zanieczyszczenia70°C
Temperatura robocza20°C
Temperatura otoczenia Wybierz swoje obliczenia
Z technologią Bearinx
Dodaj pozostałe warunki.
Emisje CO₂e
Do produkcji info_outline
-
Trwałość znamionowa
Całkowita trwałość znamionowa (Lh10)
-
Statyczny współczynnik bezpieczeństwa (S0)
-